Industry News

Whole-Genome Sequencing Expands the MRD Detection Window

Expanded variant tracking and MAESTRO enrichment target solid tumor types where ctDNA signal has been hardest to detect

Written bySharon Dong, MSc
| 5 min read
Clinical lab scientist preparing plasma samples for whole-genome sequencing MRD circulating tumor DNA analysis
Register for free to listen to this article
Listen with Speechify
0:00
5:00

In solid tumor diagnostics, the most persistent post-treatment challenge is not detecting cancer but confirming its absence. Conventional imaging cannot reliably identify microscopic residual tumor burden after surgery or systemic therapy, and MRD testing, which detects circulating tumor DNA (ctDNA) in blood plasma after curative-intent treatment, has emerged as the primary strategy to fill that gap. Postoperative ctDNA fractions can fall below 0.01 percent of total cell-free DNA, demanding sequencing platforms that combine breadth, sensitivity, and specificity in a single workflow.

Abbott announced the commercial availability of its next-generation Oncodetect MRD test, marking the transition from whole-exome to whole-genome sequencing and introducing an enhanced version of a tumor-enrichment method originally developed at the Broad Institute of MIT and Harvard. Genomic Health Inc., a wholly owned Abbott subsidiary, performs the test in its CLIA-certified, high-complexity laboratory. Abbott has not sought FDA clearance or approval and offers the test as a laboratory-developed test (LDT).


WGS Over Exome: Why the Variant Count Drives Sensitivity

The shift from whole-exome to whole-genome sequencing (WGS) is the change that drives the test's expanded detection profile. The prior-generation Oncodetect assay tracked up to 200 patient-specific somatic single-nucleotide variants from a formalin-fixed, paraffin-embedded (FFPE) tumor biopsy; the next-generation test covers as many as 5,000, a 25-fold expansion according to Abbott's product specifications. Broader variant coverage substantially increases the probability that tumor-derived DNA will appear in any plasma draw, which is especially relevant for low-shedding cancers: prostate, hormone receptor-positive breast, kidney, and early-stage lung.

MAESTRO (minor allele enriched sequencing through recognition oligonucleotides) is the enrichment technology at the core of the assay, first described in a 2022 Nature Biomedical Engineering study that found the method tracks thousands of mutations using up to 100-fold less sequencing than conventional hybrid-capture duplex sequencing. Short allele-specific oligonucleotide probes capture mutant DNA from cell-free plasma; after hybridization, unbound wild-type DNA is washed away and the enriched fraction undergoes duplex sequencing. Abbott holds exclusive rights to MAESTRO, enhanced it for clinical deployment, and reports enrichment of up to approximately 1,000-fold, a limit of detection (LoD) below one part per million (ppm) under high-end input conditions, and greater than 99 percent analytical specificity, all from internal presentations dated August 2026; these figures represent manufacturer-reported specifications awaiting peer-reviewed validation.


What Does the Clinical Evidence Show Across Tumor Types?

Three tumor type datasets support the next-generation Oncodetect test at launch: one published study and two conference-presented analyses, each with important scope limitations that laboratory directors should weigh. A Clinical Cancer Research study by Rhoades et al. (August 2026) tested the MAESTRO-based assay in serial samples from patients with locally advanced esophageal cancer after curative-intent therapy; the assay detected ctDNA before clinical relapse in all 14 patients who experienced recurrence, achieving 100 percent sensitivity in that subset. The small recurrence cohort limits generalizability, but the result establishes proof-of-concept in a low-shedding tumor type where liquid biopsy sensitivity has historically been constrained.

A prospective sub-study of the Phase 2/3 PARTNER trial (NCT03150576), presented at ASCO 2026, evaluated WES and WGS ctDNA assays in 66 patients with triple-negative breast cancer (TNBC) at a median follow-up of five years. Cumulative 3-year sensitivity for distant recurrence was 88.8 percent with WGS versus 35.3 percent with WES, approximately a 2.5-fold improvement, and the WGS approach yielded a roughly threefold higher hazard ratio for distant recurrence (HR 52.1 versus 15.2). A limited number of recurrence events constrains the confidence intervals, though the directional advantage is consistent with the assay's broader variant architecture.

At ESMO 2026, the Beta-CORRECT study poster reported a 30 percent absolute improvement in sensitivity for recurrence within two years using the next-generation WGS assay versus the first-generation test at a single post-surgical timepoint in stage II–IV colorectal cancer patients. These data have not yet been peer-reviewed. The CORRECT-II trial (NCT05210283), conducted with the NSABP Foundation and NRG Oncology in stage II and III colorectal cancer, is designed to generate the prospective clinical utility evidence that payer programs and guidelines require.

"We've spent decades getting better at treating cancer once we find it. The next chapter is about understanding what may be happening at the molecular level during and after treatment," said Rick Baehner, divisional vice president and chief medical officer, precision oncology, Abbott's cancer diagnostics business. "MRD represents an important evolution in precision oncology, helping move cancer care beyond waiting for signs of recurrence toward more informed decisions throughout a patient's care."


What Lab Directors Need to Know Before Ordering the Oncodetect Test

FFPE tissue access and initial turnaround time are the two practical constraints that most directly affect laboratory adoption of the Oncodetect test. An FFPE tumor specimen must be submitted first to generate the patient's personalized variant fingerprint via WGS, adding approximately two to three weeks before the first surveillance blood draw can be processed. The test reports results as a quantitative ctDNA level in mutant tumor molecules per milliliter (MTM/mL), enabling longitudinal disease-signal tracking rather than a binary positive/negative call.

Laboratories ordering the Oncodetect test need not hold their own CLIA high-complexity certification for this specific assay, as Genomic Health Inc.'s CLIA-certified facility performs all testing. Clinical teams must be prepared to interpret quantitative ctDNA results, an area where formal decision guidance is still developing across the field.

No ctDNA MRD assay holds FDA clearance or approval for solid tumor detection. Tumor-informed assays require baseline tissue sequencing to build a personalized variant panel; tumor-naive assays work from plasma alone and skip that step. Each category carries distinct tradeoffs in sensitivity, turnaround time, and reimbursement trajectory.

The following specifications cover the test's analytical performance, specimen requirements, regulatory status, and active clinical program as of its October 2026 commercial launch:

  • Sequencing platform: WGS with MAESTRO probe-based tumor DNA enrichment
  • Variants tracked: Up to 5,000 patient-specific single-nucleotide variants (Abbott specifications)
  • Limit of detection: Below 1 ppm under high-end input conditions (internal Abbott data; peer-reviewed validation pending)
  • Analytical specificity: Greater than 99 percent (internal Abbott data)
  • Baseline specimen: FFPE tumor tissue for WGS variant discovery
  • Surveillance specimen: Serial peripheral blood draws
  • CLIA complexity: High complexity; performed at Genomic Health Inc., CLIA-certified
  • FDA status: LDT; not FDA cleared or approved
  • Quantitative output: CTdNA level as MTM/mL (mutant tumor molecules per milliliter)
  • EHR integration: Available in leading EHR systems per Abbott
  • Active study tumor types: Colorectal, TNBC, esophageal, prostate, lung, kidney, HR+ breast, and others

Reimbursement: Where Does the Next-Generation Oncodetect Test Stand?

Abbott has not yet confirmed Medicare or commercial payer coverage for the next-generation Oncodetect test, making reimbursement the key variable for laboratories evaluating clinical adoption. The prior-generation Oncodetect test received Medicare coverage through the MolDX local coverage determination (LCD) program for colorectal cancer MRD monitoring, establishing a reimbursement precedent that the next-generation version can build on once it completes the required technical assessment process. Laboratory directors should confirm coverage status directly with Abbott before deployment; testing outside established LCD indications may require prior authorization.

The table below summarizes the test's technical architecture, regulatory status, and current validation evidence to support procurement and adoption decisions:

ParameterNext-Generation Oncodetect (Abbott)
Sequencing approachWhole-genome sequencing (WGS)
Tumor enrichmentMAESTRO probe hybridization
Tumor tissue requiredYes (FFPE)
Variants trackedUp to 5,000 patient-specific
LoD (manufacturer-reported)Below 1 ppm (high-end inputs)
Analytical specificity>99% (internal Abbott data)
CLIA complexityHigh complexity
FDA statusLDT; not cleared or approved
Medicare coverageNot yet confirmed for next-gen version
Peer-reviewed validationEsophageal cancer (CCR, Aug 2026); TNBC (ASCO 2026 abstract); CRC (ESMO 2026 poster)

Oncodetect MRD Testing: Early Evidence, Pending Proof of Clinical Utility

Abbott's next-generation Oncodetect test enters the market with published validation in one tumor type and conference-presented data in two others; the central challenge for the platform, and for solid tumor MRD testing broadly, is generating interventional evidence that acting on a positive ctDNA result improves patient outcomes. Its WGS-plus-MAESTRO architecture offers a technically credible path to sub-ppm detection at scale, and LDT status under CLIA high-complexity regulations provides an established framework for clinical deployment while FDA-cleared solid tumor MRD assays remain absent from the market. Before routine adoption, lab directors should monitor peer-reviewed publication of the PARTNER and Beta-CORRECT datasets, track MolDX LCD activity for an Oncodetect-specific coverage determination, and assess FFPE tissue access and EHR readiness.


This article is based on a press release issued by Abbott and was produced under Today's Clinical Lab's AI Editorial Guidelines.

Add Today's Clinical Lab as a preferred source on Google

Add Today's Clinical Lab as a preferred Google source to see more of our trusted coverage.

About the Author

  • sharon dong black and white

    Sharon Dong, MSc, BSc (Hons), joined LabX Media Group (LMG) in 2026 as a Product News & Intelligence Editor. She has a background in cellular biology, microbiology, immunology, and molecular genetics. She is an experienced science education and outreach facilitator. Sharon is passionate about communicating science in ways that are clear, engaging, and accessible to a broad audience. In her free time, she enjoys solving jigsaw puzzles and cooking. Sharon can be reached at sdong@labxmediagroup.com.

    View Full Profile

Related Topics

Loading Next Article...
Loading Next Article...