Performance of Commonly Used COVID-19 Lateral Flow Tests for Kids below Par
The tests fall short of minimum criteria set by WHO, US, and UK device regulators
The performance of lateral flow (antigen) tests commonly used to detect COVID-19 infection in children falls short of the minimum criteria set by the World Health Organization (WHO) and US and UK device regulators, finds a pooled data analysis of the available evidence on eight different tests, published in the journal BMJ Evidence-Based Medicine.
The findings cast doubt on the effectiveness of their use in widespread testing in schools, suggest the researchers.
Lateral flow (antigen) tests have been widely used to pick up children with SARS-CoV-2, the virus responsible for COVID-19 infection, in schools and kindergarten.
The accuracy of these tests in adults is highly variable and often substantially lower than that reported by manufacturers. But it’s not clear how well they perform when used in children in real life.
In a bid to plug this knowledge gap, the researchers trawled research databases and pre-print servers, looking for studies published between 2020 and May 2021 that compared the accuracy of lateral flow antigen tests with swab (PCR) tests, considered the reference standard, in children.
They found 17 relevant studies (12 peer reviewed journal studies and five pre-print studies), published in English. These involved 6355 children and eight antigen tests from six different brands.
In 11 of the test evaluations, samples were collected from the throat and nose; in the rest samples were collected only from the nose. One study involved supervised collection of samples; all the others involved sample collection by trained staff.
The data from all 17 studies were pooled to measure the diagnostic sensitivity and specificity of these tests. Sensitivity indicates how well a test picks up people who have a disease/infection; specificity indicates how well a test picks up those who don’t.
The overall sensitivity of the evaluated tests was just over 64 percent; the overall specificity was just over 99 percent. The researchers then restricted the analyses to children with and without symptoms.
Among children with symptoms, the pooled diagnostic sensitivity was just under 72 percent and the pooled diagnostic specificity was just under 99 percent, based on 3413 children in 13 studies.
Among children without symptoms the pooled diagnostic sensitivity was just over 56 percent while the pooled diagnostic specificity was just over 98.5 percent, based on 2439 children in 10 studies.
These observed differences in test performance between children with and without symptoms show that sensitivity and specificity are not inherent test characteristics, say the researchers.
They highlight certain limitations to their findings. Inadequate reporting precluded quality assessment of most of the studies. And the review was restricted to eight tests: there are more than 500 lateral flow tests for professional use on the market.
None of the included studies assessed sample collection by untrained people or self-testing, which likely worsens performance. And the findings might not be applicable to future SARS-CoV-2 variants or vaccinated children either, the researchers acknowledge.
But they write: “Sensitivity estimates of antigen tests varied broadly among studies and were substantially lower than reported by manufacturers,” although the intended use of most tests is limited to people with symptoms, so performance data reported by manufacturers usually refer only to those with symptoms, they add.
“Less variation and only minor discrepancies to performance claims by manufacturers were observed for specificity estimates across studies.”
But they conclude: “Taking into account test-specific pooled results, no test included in this review fully satisfied the minimum performance requirements as recommended by WHO…, the US [Food and Drug Administration], …or the Medicines and Healthcare products Regulatory Agency (MHRA) in the UK.
“This may affect the planned purpose of the broad implementation of testing programs.”
While lateral flow tests complement PCR tests, extend test capacity, and come into their own when a short turnaround is essential, they nevertheless “come at the price of lower diagnostic accuracy, most notably a lower diagnostic sensitivity, which increases the risk of missing cases, including those with pre-symptomatic infection who have yet to enter the most infectious period,” they note.
Whether this can be compensated for with frequent testing remains a moot point, they add.